Formulation compatibility program

An API that is stable on its own can still fail in the tablet. Our program tests your solid form against the excipients, the process and the moisture it will meet in the product, chemically and in the solid state, before a formulation is locked.

Why it matters

Most incompatibilities are found too late

Drug–excipient interactions usually surface during formulation stability studies, months after the excipients were chosen. By then the composition, the process and often the clinical supply depend on it. Changing an excipient at that stage means new batches, a new stability programme and, sometimes, a delay to the clinic.

Chemical degradation is only part of the risk. A salt can disproportionate back to its free form in contact with a basic excipient. A metastable polymorph can convert during wet granulation or compression. An amorphous dispersion can start to crystallize when a hygroscopic excipient draws in water. These are solid-state events, and a purity assay alone will not show them.

The program looks for both kinds of failure at the same time, early enough for the answer to change the formulation rather than delay it.

What we do

What the program covers

The study is built around your API, the dosage form you intend and the excipients you are considering.

Excipient compatibility screening

Binary and multi-component mixtures of the API with candidate fillers, binders, disintegrants, lubricants and surfactants, stored under accelerated conditions.

Chemical stability

Assay and related substances on every mixture, with identification of the degradation products that form only in the presence of a specific excipient.

Solid-form stability in the mixture

Detection of polymorphic conversion, salt disproportionation, hydrate formation or loss of amorphous character in contact with each excipient.

Process stress

Simulation of the steps the formulation will see, such as milling, wet granulation, drying and compression, to find which ones change the API.

Moisture and microenvironment

Moisture uptake of the blends and the effect of excipient pH and water activity on the stability of the API.

Ranking and recommendation

Excipients classed as compatible, conditional or to avoid, with the evidence for each, so the formulator can choose with confidence.

How we work

How the program runs

The design is agreed with you before any mixture is prepared, and adjusted as results come in.

Baseline of the API

The solid form, purity and degradation pathways of the API are established first, so every change seen in a mixture can be attributed correctly.

Excipient panel and design

The excipient list, ratios, storage conditions and time points are defined with you, based on the intended dosage form and process.

Mixtures and stress

Mixtures are prepared and stored under accelerated temperature and humidity, with process-stressed samples where the formulation route calls for it.

Chemical analysis

Samples are analysed at each time point for assay and degradation products with stability-indicating methods.

Solid-state analysis

The same samples are examined by diffraction, thermal analysis and spectroscopy to detect changes in the solid form.

Interpretation and reporting

Chemical and solid-state results are read together and summarised in a compatibility matrix with a recommendation for each excipient.

Instrumentation

Techniques used

Compatibility is judged on two independent lines of evidence: what happens to the molecule, and what happens to the solid.

HPLC / UPLCLC-MSX-Ray Powder Diffraction (XRPD)Differential Scanning Calorimetry (DSC)Thermogravimetric Analysis (TGA)FT-IR and FT-RamanSolid-State NMRDynamic Vapour Sorption (DVS)Karl-Fischer titrationICH stability chambers
Deliverables

What you receive

The program ends with a detailed technical-scientific report, written for the formulation team and usable in your development documentation.

  • Study design: excipients, ratios, conditions and time points
  • Chemical stability data for every mixture and time point
  • Solid-state data showing whether the API form changed in each mixture
  • Identification of excipient-specific degradation products
  • Compatibility matrix: compatible, conditional or to avoid
  • Recommendations for the formulation and for the stability programme
Questions

Frequently asked questions

How is this different from preformulation?

Preformulation characterizes the API on its own. The compatibility program tests the API together with the excipients and the process it will meet in the product. It usually follows preformulation and precedes the first formulation batches.

Which excipients can you test?

The excipients you are considering for your dosage form. If the list is still open, we propose a panel based on the formulation route and on what is known about the molecule.

Why look at the solid state as well as purity?

Because several common failures, such as salt disproportionation, polymorphic conversion or crystallization of an amorphous dispersion, change the API without degrading it. A purity assay does not detect them; diffraction and thermal analysis do.

How long does the program take?

It depends on the number of excipients, the storage conditions and the time points. We agree the duration with the study design, and share results at each time point rather than only at the end.

How much API do you need?

It depends on the size of the excipient panel and on the techniques involved. We confirm the quantity when the study is designed, and keep it as low as the methods allow.

Can you run it on a potent or controlled API?

Yes. Our laboratory handles high-potency APIs up to OEB5 and controlled substances under Ministry of Health authorization, within its AIFA GMP certification.

Test the formulation before you build it

Tell us the API, the dosage form and the excipients you are considering. We will propose a study design, the material requirement and a timeline.

Related services

Explore what comes next